N2 Generator and Other Supporting Equipment



1. N2 Generator
The N2 Generator will produce Nitrogen with purity 99,999%.
Some Key features of the system are the following:
- The following impurities should be detectable at the produced N2 at levels equal or preferably less than the following:
- O2 ≤ 10ppm
- H2O ≤ 4 ppm
- CO2 ≤ 100 ppm
- CO ≤ 1 ppm
- NOx ≤ 10 ppm
- Oil content ≤ 1 ppm
- N2 Production Capacity: At least 8m3/h at 20oC and no less than 6m3/h at 40oC
2. Water Chiller
The Water Chiller will be used to cool the new production equipment through a water closed circuit. Some key features of the tool are th following:
- Nominal cooling power at least 13kW.
- Minimum cooling water supply should be 60 liters / minute.
- Minimum cooling water pressure should be 5 bar.